Instruction Manual
Model 1823A 2.4 GHz Universal Frequency Counter
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Instruction Manual

Instruction Manual Model 1823A 2.4 GHz

Page 2 - Introduction

10 Allow more than 30 minutes for the unit to warm up so that it is stabilized and ready for use. 3. OPERATION 3-

Page 3

11 the knob out and rotating it varies the level from negative to positive around the mid point. INPUT C, BNC : Input for frequency

Page 4 - 1. PRODUCT DESCRIPTION

12 e. TOTAL A. When this mode is selected, the unit counts cycles of the input A signal and continuously displays that count. f. T.l (AB). When

Page 5

13 FIG (3) REAR PANEL AC INLET: AC power input connector VOLTAGE SELECTOR: Selects the AC Power (115 V or 230 V)

Page 6 - FREQUENCY (Hz)

14 RS-232C CONNECTOR : Connector for serial interfacing with a computer. 3-2. Operating Instruction Below is the basic operatin

Page 7

15 DC coupling position. 3-3-2 INPUT C (80 MHz to 2.4 GHz) CAUTION THE MAXIMUM INPUT LIMIT TO THIS INPUT IS 3 Vrms MAXIMUM OVER THE I

Page 8

16 3-6. Time Interval Measurements(AB) In time interval mode, unit measures the elapsed time from a selected edge of the input A w

Page 9

17 3-7. Frequency Ratio Measurements (A/B) In this mode of operation, the counter displays the ratio of the frequency applied to

Page 10 -   

18 3-8. Use of RS-232C Serial Interfacing 1) Hardware/Software Requirements . IBM PC/XT/AT or compatible computer . Microsoft Windo

Page 11

19 4. MAINTENANCE CAUTION IT IS ESSENTIAL FOR SAFETY TO PROPERLY MAINTAIN AND SERVICE THIS INSTRUMENT WARNING VOLTAGES WITHIN THIS INSTRUME

Page 12

2 Introduction Thank you for purchasing our product. Electronic measuring instruments produced by us are high technology products made un

Page 13 - Made in Korea

20 5. OTHERS 5-1. BNC Cable Considerations Accuracy of radio frequency measurements can be affected by connections between signal sou

Page 14 - CAUTION

21 5-3. Line Frequency Measurements Use of the attenuator, low pass filter, and/or x10 probe is advisable when measuring line frequenc

Page 15

22 Limited One-Year Warranty B&K Precision Corp. warrants to the original purchaser that its product and the component parts thereof, wil

Page 16

23 Model Number: ______________ Date Purchased:__________ Service Information Warranty Service: Please re

Page 17

24 PN: 481-542-9-001 Printed in Korea 2004 B&K Precision Corp. V4.8.2014 22820 Savi Ranch Parkway Yorba Lind

Page 18

3 CONTENTS 1. PRODUCT DESCRIPTION 1-1. Introduction ------------------------------------------------------ ( 4 ) 1-2. Technical

Page 19 - WARNING

4 1. PRODUCT DESCRIPTION 1-1. Introduction This reciprocal UNIVERSAL COUNTER series are microprocessor controlled instruments

Page 20 - 5. OTHERS

5 1-2. Technical Specifications  INPUT A CHARACTERISTICS  FREQUENCY RANGE : 0.1 Hz to 100 MHz (DC Coupled) 30 Hz to 100 MHz (AC Coupled)  S

Page 21

6  MAX. INPUT VOLTAGE LEVEL FIG 1. MAX. Input Level. (Input A,B)  INPUT B. CHARACTERISTICS = Same as Input A  TI

Page 22 - Limited One-Year Warranty

7  INPUT C. CHARACTERISTICS  FREQUENCY RANGE: 80 MHz to 2.4 GHz  SENSITIVITY: 25 mV from 80 MHz to 150 MHz 20 mV from 150 MHz to 2.0 G

Page 23

8 displayed. When Hold is released, a new measurement begins.  GATE TIME : Depending on input frequency < 10 mS-----

Page 24

9  Power cord-----------------------------------------------------------------1  Spare Fuse---------------------------------------------------