Query
Syntax: [:SOURce:]SWEEP:STOP?[<ws>MAXimum|MINimum]
Examples: SWEEP:STOP ?
SWEEP:STOP ? MAX
Response: NR3
4.13.1.11 PHASe adjust
This command controls the phase adjustment
Arguments
Type: Numeric
Units: one (degrees implied)
Range: -180 to +180 (other values converted to this range)
Rounding: to integer
Command Type: Setting or Query
Setting
Syntax: [:SOURce:]PHASe<ws><phase>
[:SOURce:]PHASe<ws>MINimum|MAXimum
Examples: [:SOURce:]PHASe 500NS
Query
Syntax: [:SOURce:]PHASe?[<ws>MINimum|MAXimum]
Response: NR3
4.13.1.12 PULSe setting
The following commands control the pulse function:
Note that width +0.6*(rise + fall) < period in order to have valid values. Width < Period – 10 ns
4.13.1.12.1 PULSe PERiod
This command sets the pulse period to the specified value.
NOTE: This also sets the pulse frequency.
Arguments
Type: Numeric
Units: S, mS, uS, nS
Range: 100nS-1000S
Rounding: 4 digits
Command Type: Setting or Query
Setting
Syntax: [:SOURce:] PULse: PERiod <ws><value>
[:SOURce:] PULse: PERiod <ws>MINimum|MAXimum
Examples: [:SOURce:] PULse: PERiod 500NS
Query
Syntax: [:SOURce:] PULse: PERiod?[<ws>MINimum|MAXimum]
Response: NR3
4.13.1.12.2 PULse WIDth
This command pulse width to the specified value.
Arguments
Type: Numeric
Units: S, mS, uS, nS
Range: 20 nS minimum; maximum defined by period and transition (see note above)
Rounding: 4 digits
Command Type: Setting or Query
Setting
Syntax: [:SOURce:]PULse:WIDth<ws>< value >
[:SOURce:] PULse:WIDth <ws>MINimum|MAXimum
Examples: [:SOURce:] PULse:WIDth 500NS
Query
Commentaires sur ces manuels