BK Precision 4084AWG Manuel d'instructions Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 61
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
onlinecomponents.com
4080 series Function & Arbitrary/Function Generators Instruction Manual
6
2. SPECIFICATIONS
2.1 Function Generator
Waveform Characteristics
Main Waveforms: Sine, square
Waveform Amplitude resolution: 12 bits
Sample Rate: 200MSa/s (4084, 4084AWG, 4085, 4086, 4086AWG)
300MSa/s (4087)
Sine:
Harmonic Distortion of Sine Wave:
- 50dBc (frequency ≤ 5MHz)
- 45dBc (frequency ≤ 10MHz)
- 40dBc (frequency ≤ 20MHz)
- 35dBc (frequency ≤ 40MHz)
- 30dBc (frequency > 40MHz)
Total Harmonic distortion: 0.1% (20Hz ~ 100kHz)
Square:
Rise and Fall Time of Square Wave: ≤15ns
Note: Test conditions for harmonic distortion, sine distortion, rise/fall time: Output
Amplitude 2Vp-p, Environmental temperature: 25±5
Build in standard and complex (arbitrary) waveforms:
27 build-in standard and complex waveforms.
Sine, Square, Triangle, Positive Ramp, Falling Ramp, Noise, Positive Pulse, Negative
Pulse, Positive DC, Negative DC, Stair wave, Coded Pulse, Full wave rectified,
Half-wave rectified, Sine transverse cut, Sine vertical cut, Sine phase modulation,
Logarithmic, Exponential, Half-round, SINX/X, Square root, Tangent, Cardiac,
Earthquake, Combination
Waveform Length: 4096 dots
Amplitude Resolution: 10 bits
Pulse Wave:
Duty Cycle: 0.1% ~ 99.9% (below 10kHz), 1% ~ 99% (10kHz ~ 100kHz)
Rise/Fall Time: ≤100ns Duty cycle 20%
DC signal characteristics:
DC range: ≤ 10mV – 10V (high impedance)
DC Accuracy: ≤ ±5% of setting +10mV (high impedance)
Module for user defined arbitrary waveform generation (models 4084AWG and 4086AWG only)
Number of memory locations for arbitrary waveforms: 8
Length of waveforms8~16000 points
Resolution of waveform amplitude10 bits
Frequency range100μHz~100kHz